Treatment and recover of waste water containing acetone |
Type:FX-201.1, hydrophobic silica zeolite adsorbent Unit of application in:(Sinopec Shanghai Gao-Qiao Petro-chemical Corp.) Background: In some perto-chemical plant, the waste water containing acetone is usually treated with a process by ail sweeping, the efficiency of which is low and resulting in second contamination. In new process using FX-201.1 adsorbent, the acetone contained in waste water can be effetely removed and recovered.
|
1) Major process parameters Adsorption: 20~32℃,space velocity 2.5~3.0, 14~16g waste water/g adsorbent,动Dynamic adsorption capacity 60 mg acetone/g adsorbent. Desorption: 180℃,5 hr,N2 as carrying gas. Quality level: Acetone content in treated waste water < 50ppm;De-acetone efficiency 98%; Concentration of acetone in adsorption solution 8.0%.
2)Adsorption of acetone, phenol and water
|
Acetone |
phenol |
water |
Tem.(℃) |
20 |
50 |
26 |
Adsorption(g/100 g adsorbent) |
10.8 |
11.2 |
0.6 |
3)Test apparatuses |
|
上海高桥石化化工厂,复旦大学。“疏水硅沸石处理含酮废水与回收丙酮”,科学技术成果评审证书,编号(95)沪高科鉴字06号 。 点击下载 【2】 上海高桥石化化工厂,“疏水硅沸石处理含酮废水与回收丙酮”课题小试报告。 点击下载 |
|
|